Skip to main contentSkip to navigationSkip to contactAccessibility (Alt+A)

Keyboard Shortcuts

  • Alt + A: Open accessibility settings
  • Tab: Navigate to next element
  • Shift + Tab: Navigate to previous element
  • Enter or Space: Activate buttons and links
  • Escape: Close dialogs and menus
  • Arrow keys: Navigate within menus and sliders
  • Home: Go to beginning of list
  • End: Go to end of list
EmersonEIMS — Reliable Power. Without Limits.
HOMEABOUT
INDUSTRIES
CONTACT
Get Quote

B2BEmersonEIMS serves commercial, industrial, healthcare, telecom, hospitality, government & contractor clients.• Engineering-led • SLA-backed • Documented commissioning

Talk to an engineerWhatsApp+254 768 860 665

Services Directory

View all services →

Power & Generators

  • Cummins Generators (3-yr warranty)
  • Generator Repairs & Maintenance
  • ATS / Changeovers
  • Generator Sales
  • Generator Rental
  • Generator Installation
  • Generator Spare Parts
  • Power Interruption Solutions

Renewable & UPS

  • Solar Energy Solutions
  • Commercial / Industrial Solar
  • Solar System Sizing
  • Solar Genius Pro™
  • UPS Systems
  • UPS Lab
  • Solar / UPS Hub
  • Borehole Pumps

Electrical & HVAC

  • Distribution Boards & Panels
  • Motor Rewinding
  • Motors & Drives
  • High-Voltage Systems
  • Diesel Automation
  • Industrial Controls
  • Steel Fabrication
  • AC / HVAC Installation

Specialised & AI Suites

  • Hospital Incinerators
  • Incinerator Construction Guide
  • Building Engineering Suite
  • EIMS PRO Workspace
  • AquaScan Pro™
  • Generator Oracle™
  • Diagnostics Hub
  • Troubleshooting Wizard

Maintenance Hubs

  • Generator Maintenance
  • Solar Maintenance
  • HVAC Maintenance
  • Borehole Maintenance
  • Electrical Maintenance
  • Motors Maintenance
  • Incinerator Maintenance
  • Fabrication & Welding

Resources & Tools

  • Resources & Learning Hub
  • Knowledge Base
  • Technical Bible
  • Power Calculators
  • Fault Code Database
  • Blog & Articles
  • FAQ
  • Emergency Response Guide

Service Areas

  • All Kenya — 47 Counties
  • Nairobi
  • Mombasa
  • Kisumu
  • Nakuru
  • Kiambu
  • All Service Locations
EMERSONEiMS

Engineering-grade reliability for East Africa's critical infrastructure. Power systems built to perform.

  • LinkedIn↗
  • Twitter↗
  • Facebook↗

Company

  • About Us
  • All Services
  • Book a Service
  • Project Gallery
  • Case Studies
  • Industries Served
  • Careers
  • Contact Us

Quick Links

  • Generator Sales
  • Solar Energy
  • Diagnostic Suite
  • Solar / UPS Hub
  • Generator Oracle
  • Knowledge Base
  • FAQ

Contact

  • Nairobi HQEmbakasi, off Airport North Road, Nairobi
    (Near KEMSA Head Office)
  • Department Emails
    • General Inquiriesinfo@emersoneims.com
    • Service Coordinationemersoneimservices@emersoneims.com
    • Generator Deskgenerators@emersoneims.com
    • Solar & UPS Desksolar@emersoneims.com
    • Sally — Direct Accountsally@emersoneims.com
  • Phone
    +254782914717
    +254768860665

© 2026 Emerson EiMS. All rights reserved.

PROTECTED BY GENERATOR ORACLE / EMERSONEIMS
Privacy PolicyTerms of Service
ENGINEERED IN NAIROBI, KENYA
SUResourcesSolar & UPS Intelligence Hub
VerifierSimulatorUPS LabAuditCatalogueInstallAuthenticMaintainSafetyAbusePQLifecycleDocs PackLearnDiagnosticsSolar/UPSLibrary
Audience
  1. Home/
  2. Resources/
  3. Solar & UPS Intelligence Hub/
  4. UPS Live Lab

UPS Live Lab

Add UPS units and loads. The cockpit shows live input vs output, headroom, runtime, mismatch, overload and alarms in real time — same engineering family as the Smart Sizing simulator.

UPS Live Cockpit · sample dataset

Mains → UPS → Connected loads

Mains
UPS
Load
System
Input from mains
1.50kW
Live · drawing from utility
UPS capacity
5.40kW
Σ rating · pf 0.94 eff 94 %
Load demand
1.41kW
Surge 1.56 kW
Output to loads
1.41kW
Headroom 74 % · runtime 50.4 min
System schematic
Live one-line diagram
Demo data
DC busAC outputMains1.50 kWinfoInput switchclosedok~/=RectifierAC→DCokBattery bank1.4 kWhokDC busenergisedinfo=/~Inverter ×1DC→ACokStatic bypassstandbyoffCritical load1.41 kWokUPS one-line · Online double-conversionOn mains1.50 kW1.41 kW50 minCapacity 5.4 kW · load 1.4 kW
Synthetic schematic

Mains, rectifier, DC bus, battery branch, inverter, static bypass and output bus update as you add UPS units, change loads, or drop the mains. Annotations show live kW on the input/output traces and remaining battery runtime when running on battery.

⚡ Mains input
1.50 kW
🔋 UPS battery
1.40 kWh stored
🔌 UPS output
1.41 kW · 74 % headroom
🖥️ Connected loads
1.41 kW continuous
Annunciator
Live alarms
Demo data
No alarmsAll systems nominal
  • All systems nominal
Mode
Source of supply
Drop the mains to see how runtime, alarms and output respond. The UPS keeps delivering output from its battery for as long as autonomy allows.
Battery autonomy
1.40kWh
Runtime @ load
50.4min
Topology in cluster: Online double-conversion
Step 1

Pick UPS units

Add and stack UPS models. Capacity, efficiency and battery autonomy update on the cockpit live.

Demo data
Eaton·9PX 6 kVAA
6 kVA · pf 0.9 · Online double-conversion · battery 1.40 kWh · transfer 0 ms
Server rack / small data hall standby
1
APC·Smart-UPS SRT 10 kVAA
10 kVA · pf 0.9 · Online double-conversion · battery 2.10 kWh · transfer 0 ms
Critical IT infrastructure
0
Vertiv·Liebert APM 20 kVAA
20 kVA · pf 0.95 · Modular online · battery 4.20 kWh · transfer 0 ms
Modular DC UPS — N+1 module redundancy
0
Riello·Multi Sentry MST 15B
15 kVA · pf 0.9 · Online double-conversion · battery 3.20 kWh · transfer 0 ms
Industrial / commercial
0
CyberPower·OL3000ERT2U 3 kVAC
3 kVA · pf 0.9 · Online double-conversion · battery 0.72 kWh · transfer 0 ms
Workstation / network closet
0
APC·Smart-UPS SMT 2200B
2.2 kVA · pf 0.9 · Line-interactive · battery 0.48 kWh · transfer 6 ms
Office IT closet, light-duty
0
Eaton·5P 1550iB
1.55 kVA · pf 0.9 · Line-interactive · battery 0.32 kWh · transfer 4 ms
Single rack / desktop tower
0
Generic OEM·2 kVA Line-InteractiveF
2 kVA · pf 0.7 · Line-interactive · battery 0.24 kWh · transfer 8 ms
Light desktop only — verify documentation
0
Step 2

Add loads

Tap to add. The cockpit shows continuous draw, surge, headroom and any mismatch (e.g. cooker on UPS).

Demo data
🖥️Computer (desktop)
250 W · pf 0.95 · surge ×1.2 · IT
0
🗄️Rack server
600 W · pf 0.95 · surge ×1.3 · IT
2
🌐Network switch
60 W · pf 0.95 · surge ×1.1 · IT
2
🖼️Monitor 27"
45 W · pf 0.95 · surge ×1.1 · IT
2
🧊Fridge / freezer
200 W · pf 0.75 · surge ×4.0 · Appliance
0
📺TV (LED)
110 W · pf 0.9 · surge ×1.1 · Appliance
0
💡LED bulb
9 W · pf 0.9 · surge ×1.0 · Lighting
0
🍳Electric cooker⚠ not advised on UPS
2400 W · pf 1 · surge ×1.0 · Heat
0
🧺Washing machine⚠ not advised on UPS
800 W · pf 0.7 · surge ×3.5 · Motor
0
🔥Room heater⚠ not advised on UPS
2000 W · pf 1 · surge ×1.0 · Heat
0
❄️Air conditioner 1.5HP⚠ not advised on UPS
1500 W · pf 0.85 · surge ×4.0 · Motor
0
⛽Borehole pump 1HP⚠ not advised on UPS
750 W · pf 0.85 · surge ×4.0 · Motor
0
Use this with

Connected workflow

Take the UPS configuration into the Smart Sizing Simulator for a full system view, audit pricing through Quotation Audit, walk the install in Installation Visualizer, and validate with Diagnostics, Maintenance Planner and Power Quality. Cross-check models in Product Intelligence.

One platform · 17 tools

Connected workspace

Continue the engineering loop — sizing, audit, intelligence, diagnostics, solar/UPS, library.

  • VerifierCombination VerifierOpen →
  • SimulatorSmart SizingOpen →
  • AuditQuotation AuditOpen →
  • CatalogueProduct IntelligenceOpen →
  • InstallInstallation VisualizerOpen →
  • AuthenticAuthenticity CheckOpen →
  • MaintainMaintenance PlannerOpen →
  • SafetySafety & FireOpen →
  • AbuseAbuse PredictorOpen →
  • PQPower QualityOpen →
  • LifecycleLifecycle CostOpen →
  • Docs PackDocumentation PackOpen →
  • LearnLearning ModeOpen →
  • DiagnosticsDiagnosticsOpen →
  • Solar/UPSSolar & UPSOpen →
  • LibraryLibraryOpen →
Sample values labelled Demo data·Hub v1.0.0-rc.1·staging·Reviewed 2026-05-03·Audit trail