Skip to main contentSkip to navigationSkip to contactAccessibility (Alt+A)
EmersonEIMS — Reliable Power. Without Limits.
INDUSTRIES
CONTACT
Get Quote

B2BEmersonEIMS serves commercial, industrial, healthcare, telecom, hospitality, government & contractor clients.• Engineering-led • SLA-backed • Documented commissioning

Talk to an engineerWhatsApp+254 768 860 665

Services Directory

View all services →

Power & Generators

  • Cummins Generators (2-yr warranty)
  • Generator Repairs & Maintenance
  • ATS / Changeovers
  • Generator Sales
  • Generator Rental
  • Generator Installation
  • Generator Spare Parts
  • Workshop Repairs & Fabrication
  • Power Interruption Solutions

Renewable & UPS

  • Solar Energy Solutions
  • Commercial / Industrial Solar
  • Solar System Sizing
  • Solar Genius Pro™
  • UPS Systems
  • UPS Lab
  • Solar / UPS Hub
  • Borehole Pumps

Electrical & HVAC

  • Distribution Boards & Panels
  • Motor Rewinding
  • Motors & Drives
  • High-Voltage Systems
  • Diesel Automation
  • Industrial Controls
  • Steel Fabrication
  • AC / HVAC Installation

Specialised & AI Suites

  • Hospital Incinerators
  • Incinerator Construction Guide
  • Building Engineering Suite
  • EIMS PRO Workspace
  • AquaScan Pro™
  • Generator Oracle™
  • Plant & Equipment Oracle
  • Diagnostics Hub
  • Troubleshooting Wizard

Maintenance Hubs

  • Generator Maintenance
  • Solar Maintenance
  • HVAC Maintenance
  • Borehole Maintenance
  • Electrical Maintenance
  • Motors Maintenance
  • Incinerator Maintenance
  • Fabrication & Welding

Resources & Tools

  • Repair Centre — 60 free guides
  • Spare Parts Marketplace
  • Sectors We Serve
  • Brands We Service
  • All Engineering Tools
  • Resources & Learning Hub
  • Knowledge Base
  • Technical Bible
  • Power Calculators
  • Fault Code Database
  • Blog & Articles
  • FAQ
  • Emergency Response Guide

Service Areas

  • All Kenya — 47 Counties
  • Nairobi
  • Mombasa
  • Kisumu
  • Nakuru
  • Kiambu
  • All Service Locations
  • East Africa
  • Kampala, Uganda
  • Dar es Salaam, Tanzania
  • Kigali, Rwanda
  • Juba, South Sudan
  • Site Directory — every page
EMERSONEiMS

Engineering-grade reliability for East Africa's critical infrastructure. Power systems built to perform.

  • X↗
  • Facebook↗

Company

  • About Us
  • All Services
  • Prices & Costs
  • Book a Service
  • Project Gallery
  • Case Studies
  • Industries Served
  • Careers
  • Contact Us

Quick Links

  • Generator Sales
  • Solar Energy
  • Diagnostic Suite
  • Solar / UPS Hub
  • Generator Oracle
  • Knowledge Base
  • FAQ

Contact

  • Nairobi HQEmbakasi, off Airport North Road, Nairobi
    (Near KEMSA Head Office)
  • Department Emails
    • General Inquiriesinfo@emersoneims.com
    • Service Coordinationemersoneimservices@emersoneims.com
    • Generator Deskgenerators@emersoneims.com
    • Solar & UPS Desksolar@emersoneims.com
    • Sally — Direct Accountsally@emersoneims.com
  • Phone
    +254782914717
    +254768860665

© 2026 Emerson EiMS. All rights reserved.

PROTECTED BY GENERATOR ORACLE / EMERSONEIMS
Privacy PolicyTerms of Service
ENGINEERED IN NAIROBI, KENYA

Keyboard Shortcuts

  • Alt + A: Open accessibility settings
  • Tab: Navigate to next element
  • Shift + Tab: Navigate to previous element
  • Enter or Space: Activate buttons and links
  • Escape: Close dialogs and menus
  • Arrow keys: Navigate within menus and sliders
  • Home: Go to beginning of list
  • End: Go to end of list
  1. Home
  2. /
  3. Repair Centre
  4. /
  5. Generator Repair & Troubleshooting

Generator Repair & Troubleshooting

Diagnosis and repair guidance for diesel generating sets — starting faults, protective shutdowns, output problems, cooling, fuel and control systems. Written for technicians working on real plant, with the safety constraints stated rather than assumed.

Starting and crankingfaults3 guidesProtective shutdowns — oilpressure,…2 guidesOutput faults — novoltage,…3 guidesFuel system diagnosis3 guidesCooling system diagnosis1 guideController andcommunication…3 guidesTransfer switching andload…2 guidesGenerator
Fault domains for Generator. Solid outline means a published guide covers that domain; dashed means the guide is not yet written. 7 of 7 covered.

What this covers

  • ▪Starting and cranking faults — Generator Cranks But Will Not Start, Starter Motor Clicks But Will Not Crank, Generator Starting Battery Not Charging
  • ▪Protective shutdowns — oil pressure, coolant temperature, overspeed — Generator Low Oil Pressure Shutdown, Generator Overheating and High Coolant Temperature Shutdown
  • ▪Output faults — no voltage, unstable voltage, frequency problems — Generator Runs But Produces No Voltage, Generator Voltage Unstable or Hunting, AVR Fault Diagnosis
  • ▪Fuel system diagnosis — Generator Starts Then Stops, Diesel Fuel Contamination, Generator Excessive Smoke
  • ▪Cooling system diagnosis — Generator Overheating and High Coolant Temperature Shutdown
  • ▪Controller and communication faults — Reading a Generator Controller Alarm Correctly, Generator Starts in Manual But Not in Auto, Reading J1939 Engine Fault Codes
  • ▪Transfer switching and load acceptance — ATS Not Changing Over, Generator Will Not Transfer Back to Mains

Diagnosis guides

  • Generator Cranks But Will Not Start — Diagnosis and Repair

    Cummins, Perkins, Caterpillar, Volvo Penta, Deutz, Doosan, FG Wilson, SDMO and other electronic or mechanically governed diesel sets

    10 diagnostic steps · intermediate · technician

  • Generator Starts Then Stops — Diagnosis and Repair

    Cummins, Perkins, Caterpillar, Volvo Penta, Deutz, Doosan, FG Wilson, SDMO and other electronically or mechanically governed diesel sets

    10 diagnostic steps · intermediate · technician

  • Generator Low Oil Pressure Shutdown — Diagnosis and Repair

    All diesel generating sets with oil pressure protection — Cummins, Perkins, Caterpillar, Volvo Penta, Deutz, Doosan, FG Wilson, SDMO and others

    9 diagnostic steps · intermediate · technician

  • Generator Runs But Produces No Voltage — Diagnosis and Repair

    Brushless and brushed synchronous alternators fitted to Cummins, Perkins, Caterpillar, FG Wilson, SDMO and other sets. Stamford, Leroy-Somer, Marathon, Mecc Alte and equivalent generator ends.

    10 diagnostic steps · advanced · qualified electrician

  • Generator Voltage Unstable or Hunting — Diagnosis and Repair

    Brushless and brushed synchronous alternators with electronic AVRs, on mechanically or electronically governed diesel sets

    10 diagnostic steps · advanced · qualified electrician

  • Generator Overheating and High Coolant Temperature Shutdown

    Open and canopied diesel generating sets, single- and three-phase, standby and prime

    8 diagnostic steps · intermediate · technician

  • AVR Fault Diagnosis — Before You Replace the Regulator

    Brushless self-excited and PMG-excited alternators on diesel generating sets, single- and three-phase

    8 diagnostic steps · advanced · qualified electrician

  • Starter Motor Clicks But Will Not Crank — Diagnosis and Repair

    Diesel generating sets with electric starting, single- and three-phase, standby and prime

    8 diagnostic steps · intermediate · technician

  • Generator Starting Battery Not Charging — Diagnosis and Repair

    Diesel generating sets with electric starting, standby and prime, with engine-driven charging alternator and separate mains battery charger

    8 diagnostic steps · intermediate · technician

Related guides

Filed under another category, but they cover part of the scope above.

  • Diesel Fuel Contamination — Water, Dirt and Microbial Growth

    in Fuel & Combustion Diagnosis · 8 diagnostic steps

  • Generator Excessive Smoke — Reading Black, Blue and White

    in Fuel & Combustion Diagnosis · 9 diagnostic steps

  • Reading a Generator Controller Alarm Correctly — Why a Fault Code Is Not a Diagnosis

    in Controller Diagnostics · 8 diagnostic steps

  • Generator Starts in Manual But Not in Auto

    in Controller Diagnostics · 8 diagnostic steps

  • Reading J1939 Engine Fault Codes — What SPN and FMI Actually Tell You

    in Fault Codes & Diagnostic Messages · 8 diagnostic steps

  • ATS Not Changing Over — Automatic Transfer Switch Diagnosis

    in ATS & Changeover Panel Diagnosis · 8 diagnostic steps

  • Generator Will Not Transfer Back to Mains

    in ATS & Changeover Panel Diagnosis · 7 diagnostic steps

Want us to do the work?

These guides are written so you can diagnose the fault yourself. If you would rather an engineer handled it, our mobile workshop covers all 47 counties.

Generator Repair & Troubleshooting servicesTalk to an engineer

Related categories

  • Controller Diagnostics
  • Fuel & Combustion Diagnosis
  • Engine Mechanical Diagnosis
  • ATS & Changeover Panel Diagnosis