Skip to main contentSkip to navigationSkip to contactAccessibility (Alt+A)

Keyboard Shortcuts

  • Alt + A: Open accessibility settings
  • Tab: Navigate to next element
  • Shift + Tab: Navigate to previous element
  • Enter or Space: Activate buttons and links
  • Escape: Close dialogs and menus
  • Arrow keys: Navigate within menus and sliders
  • Home: Go to beginning of list
  • End: Go to end of list
EmersonEIMS — Reliable Power. Without Limits.
INDUSTRIES
CONTACT
Get Quote

B2BEmersonEIMS serves commercial, industrial, healthcare, telecom, hospitality, government & contractor clients.• Engineering-led • SLA-backed • Documented commissioning

Talk to an engineerWhatsApp+254 768 860 665

Services Directory

View all services →

Power & Generators

  • Cummins Generators (3-yr warranty)
  • Generator Repairs & Maintenance
  • ATS / Changeovers
  • Generator Sales
  • Generator Rental
  • Generator Installation
  • Generator Spare Parts
  • Workshop Repairs & Fabrication
  • Power Interruption Solutions

Renewable & UPS

  • Solar Energy Solutions
  • Commercial / Industrial Solar
  • Solar System Sizing
  • Solar Genius Pro™
  • UPS Systems
  • UPS Lab
  • Solar / UPS Hub
  • Borehole Pumps

Electrical & HVAC

  • Distribution Boards & Panels
  • Motor Rewinding
  • Motors & Drives
  • High-Voltage Systems
  • Diesel Automation
  • Industrial Controls
  • Steel Fabrication
  • AC / HVAC Installation

Specialised & AI Suites

  • Hospital Incinerators
  • Incinerator Construction Guide
  • Building Engineering Suite
  • EIMS PRO Workspace
  • AquaScan Pro™
  • Generator Oracle™
  • Diagnostics Hub
  • Troubleshooting Wizard

Maintenance Hubs

  • Generator Maintenance
  • Solar Maintenance
  • HVAC Maintenance
  • Borehole Maintenance
  • Electrical Maintenance
  • Motors Maintenance
  • Incinerator Maintenance
  • Fabrication & Welding

Resources & Tools

  • Repair Centre — 60 free guides
  • Spare Parts Marketplace
  • Sectors We Serve
  • Brands We Service
  • All Engineering Tools
  • Resources & Learning Hub
  • Knowledge Base
  • Technical Bible
  • Power Calculators
  • Fault Code Database
  • Blog & Articles
  • FAQ
  • Emergency Response Guide

Service Areas

  • All Kenya — 47 Counties
  • Nairobi
  • Mombasa
  • Kisumu
  • Nakuru
  • Kiambu
  • All Service Locations
  • East Africa
  • Kampala, Uganda
  • Dar es Salaam, Tanzania
  • Kigali, Rwanda
  • Juba, South Sudan
  • Site Directory — every page
EMERSONEiMS

Engineering-grade reliability for East Africa's critical infrastructure. Power systems built to perform.

  • LinkedIn↗
  • Twitter↗
  • Facebook↗

Company

  • About Us
  • All Services
  • Book a Service
  • Project Gallery
  • Case Studies
  • Industries Served
  • Careers
  • Contact Us

Quick Links

  • Generator Sales
  • Solar Energy
  • Diagnostic Suite
  • Solar / UPS Hub
  • Generator Oracle
  • Knowledge Base
  • FAQ

Contact

  • Nairobi HQEmbakasi, off Airport North Road, Nairobi
    (Near KEMSA Head Office)
  • Department Emails
    • General Inquiriesinfo@emersoneims.com
    • Service Coordinationemersoneimservices@emersoneims.com
    • Generator Deskgenerators@emersoneims.com
    • Solar & UPS Desksolar@emersoneims.com
    • Sally — Direct Accountsally@emersoneims.com
  • Phone
    +254782914717
    +254768860665

© 2026 Emerson EiMS. All rights reserved.

PROTECTED BY GENERATOR ORACLE / EMERSONEIMS
Privacy PolicyTerms of Service
ENGINEERED IN NAIROBI, KENYA
  1. Home
  2. /
  3. Repair Centre
  4. /
  5. Fuel & Combustion Diagnosis

Fuel & Combustion Diagnosis

Diesel fuel, air and combustion faults — smoke diagnosis, fuel contamination, injection and the loading problems that damage engines without any component failing. Written for Kenyan conditions, where dust loading, altitude derating and long-stored fuel matter more than temperate assumptions allow.

Smoke diagnosis — black,blue…1 guideAir restriction andturbocharger…1 guideWet stacking andlight-load…1 guideFuel contamination, waterand…1 guideInjection and combustionfaults1 guideAltitude and ambientderating1 guideFuel &Combustion
Fault domains for Fuel & Combustion. Solid outline means a published guide covers that domain; dashed means the guide is not yet written. 6 of 6 covered.

What this covers

  • ▪Smoke diagnosis — black, blue and white — Generator Excessive Smoke
  • ▪Air restriction and turbocharger faults — Air Restriction and Turbocharger Faults
  • ▪Wet stacking and light-load damage — Generator Excessive Smoke
  • ▪Fuel contamination, water and filtration — Diesel Fuel Contamination
  • ▪Injection and combustion faults — Generator Excessive Smoke
  • ▪Altitude and ambient derating — Altitude and Ambient Derating

Diagnosis guides

  • Generator Excessive Smoke — Reading Black, Blue and White

    Naturally aspirated and turbocharged diesel generating sets, mechanical and electronically controlled injection

    9 diagnostic steps · intermediate · technician

  • Diesel Fuel Contamination — Water, Dirt and Microbial Growth

    Standby and prime generating sets with bulk or day tanks, mechanical and common-rail injection

    8 diagnostic steps · intermediate · technician

  • Air Restriction and Turbocharger Faults — When the Engine Cannot Breathe

    Turbocharged and naturally aspirated diesel generating sets, with and without charge air cooling, indoor and containerised installations

    8 diagnostic steps · intermediate · technician

  • Altitude and Ambient Derating — Why a 100 kVA Set Is Not 100 kVA in Nairobi

    Diesel generating sets of any rating, naturally aspirated and turbocharged, at any site altitude and ambient temperature

    8 diagnostic steps · intermediate · technician

Want us to do the work?

These guides are written so you can diagnose the fault yourself. If you would rather an engineer handled it, our mobile workshop covers all 47 counties.

Fuel & Combustion Diagnosis servicesTalk to an engineer

Related categories

  • Generator Repair & Troubleshooting
  • Engine Mechanical Diagnosis
  • Fault Codes & Diagnostic Messages