Skip to main contentSkip to navigationSkip to contactAccessibility (Alt+A)
EmersonEIMS — Reliable Power. Without Limits.
INDUSTRIES
CONTACT
Get Quote

B2BEmersonEIMS serves commercial, industrial & institutionalcommercial, industrial, healthcare, telecom, hospitality, government & contractor clients.• Engineering-led • SLA-backed • Documented commissioning

Talk to an engineerWhatsApp+254 768 860 665

Services Directory

View all services →

Diagnostic Guides — free, no sign-up

  • Generator Repair & Troubleshooting
  • Inverter Repair & Troubleshooting
  • UPS Repair & Troubleshooting
  • PCB & Motherboard Repair
  • ATS & Changeover Panel Diagnosis
  • Fuel & Combustion Diagnosis
  • Industrial Electronics & Drives
  • Pump Diagnosis & Repair
  • Solar PV Diagnosis & Repair
  • Controller Diagnostics
  • Engine Mechanical Diagnosis
  • Motor Diagnosis & Rewinding
  • Test Instruments & Measurement
  • Fault Codes & Diagnostic Messages
  • Electrical Safety & Safe Isolation

Power & Generators

  • VOLTKA Generators (our own brand)
  • Cummins Generators (2-yr warranty)
  • Generator Repairs & Maintenance
  • ATS / Changeovers
  • Generator Sales
  • Generator Rental
  • Generator Installation
  • Generator Spare Parts
  • Workshop Repairs & Fabrication
  • Power Interruption Solutions

Renewable & UPS

  • Solar Energy Solutions
  • Commercial / Industrial Solar
  • Solar System Sizing
  • Solar Genius Pro™
  • UPS Systems
  • UPS Lab
  • Solar / UPS Hub
  • Borehole Pumps

Electrical, HVAC & Plumbing

  • Distribution Boards & Panels
  • Motor Rewinding
  • High-Voltage Systems
  • Diesel Automation
  • Industrial Controls
  • Steel Fabrication
  • AC / HVAC Installation
  • Plumbing & Water Systems

Specialised & AI Suites

  • Hospital Incinerators
  • Incinerator Construction Guide
  • Building Engineering Suite
  • EIMS PRO Workspace
  • AquaScan Pro™
  • Generator Oracle™
  • Plant & Equipment Oracle
  • Diagnostics Hub
  • Troubleshooting Wizard

Maintenance Hubs

  • Generator Maintenance
  • Solar Maintenance
  • HVAC Maintenance
  • Borehole Maintenance
  • Electrical Maintenance
  • Motors Maintenance
  • Incinerator Maintenance
  • Fabrication & Welding
  • Plumbing Maintenance
  • Welding Maintenance
  • General Maintenance

Resources & Tools

  • Repair Centre — 60 free guides
  • Spare Parts Marketplace
  • Sectors We Serve
  • Brands We Service
  • All Engineering Tools
  • Resources & Learning Hub
  • Knowledge Base
  • Technical Bible
  • Power Calculators
  • Fault Code Database
  • Blog & Articles
  • FAQ
  • Emergency Response Guide

Service Areas

  • All Kenya — 47 Counties
  • Nairobi
  • Mombasa
  • Kisumu
  • Nakuru
  • Kiambu
  • All Service Locations
  • East Africa
  • Kampala, Uganda
  • Dar es Salaam, Tanzania
  • Kigali, Rwanda
  • Juba, South Sudan
  • Site Directory — every page
EMERSONEiMS

Engineering-grade reliability for East Africa's critical infrastructure. Power systems built to perform.

  • X↗
  • Facebook↗
  • Instagram↗
  • TikTok↗

Company

  • About Us
  • All Services
  • Prices & Costs
  • Book a Service
  • Project Gallery
  • Case Studies
  • Industries Served
  • Careers
  • Contact Us

Quick Links

  • Generator Sales
  • Solar Energy
  • Diagnostic Suite
  • Solar / UPS Hub
  • Generator Oracle
  • Knowledge Base
  • FAQ

Contact

  • Nairobi HQEmbakasi, off Airport North Road, Nairobi
    (Near KEMSA Head Office)
  • Department Emails
    • General Inquiriesinfo@emersoneims.com
    • Service Coordinationemersoneimservices@emersoneims.com
    • Generator Deskgenerators@emersoneims.com
    • Solar & UPS Desksolar@emersoneims.com
    • Sally — Direct Accountsally@emersoneims.com
  • Phone
    +254782914717
    +254768860665

© 2026 Emerson EiMS. All rights reserved.

PROTECTED BY GENERATOR ORACLE / EMERSONEIMS
Privacy PolicyTerms of Service
ENGINEERED IN NAIROBI, KENYA

Keyboard Shortcuts

  • Alt + A: Open accessibility settings
  • Tab: Navigate to next element
  • Shift + Tab: Navigate to previous element
  • Enter or Space: Activate buttons and links
  • Escape: Close dialogs and menus
  • Arrow keys: Navigate within menus and sliders
  • Home: Go to beginning of list
  • End: Go to end of list
  1. Home
  2. /
  3. Services
  4. /
  5. Electrical Services
  6. /
  7. ATS & Changeovers
🔌Electrical Services

Automatic Transfer Switches & Changeovers

Seamless Power Transfer | Zero Downtime

Professional installation of automatic and manual changeover switches in Kenya. Seamless power transfer between mains and generator. All capacities from 40A to 4000A.

⚡Zero Downtime🛡️Equipment Protection🤖Hands-Free Operation✅KPLC Compliant
Get Installation Quote📞+254 768 860 665
Live engineering tools ↓Sizing calculator ↓

Get a FREE Quote

Price Range
KES 15,000 - KES 1,500,000
From KES 15,000
📝
Request a written quote
Same working day reply
📞
Call Us Now
+254 768 860 665
💬
WhatsApp
Quick Response
✉
Email Us
info@emersoneims.com
✓2-Year product warranty
✓1-Year installation warranty
✓Brand manufacturer warranty
📞24/7 Support
🇰🇪Nationwide Service
💬Free Quotation
< 10 Sec
Transfer Time
2 Years
Our Warranty
Professional
Installation
Nationwide
Service

Why Choose Our ATS & Changeovers?

Tap any card to jump straight to the matching section on this page — no other pages, no extra clicks.

⚡

Zero Downtime

Automatic transfer in under 10 seconds. Your operations continue without interruption.

Open calculator →
🛡️

Equipment Protection

Proper voltage and frequency sensing prevents damage to sensitive equipment.

Troubleshoot Q&A →
🤖

Hands-Free Operation

No manual intervention needed. Works automatically 24/7, even when no one is present.

Open calculator →
✅

KPLC Compliant

All installations meet Kenya Power regulations for backup power systems.

Troubleshoot Q&A →
👨‍🔧

Professional Installation

Certified electricians ensure safe, code-compliant installation with proper interlocking.

Open calculator →

Never manually switch between mains and generator again. Our Automatic Transfer Switch (ATS) systems provide seamless, hands-free power transfer that protects your equipment and ensures uninterrupted power supply.

EmersonEIMS supplies and installs changeover systems for all applications - from small residential units to large industrial complexes. We work with leading brands including ABB, Schneider Electric, Socomec, and trusted local manufacturers.

AUTOMATIC CHANGEOVER (ATS): Senses mains failure automatically, starts the generator, and transfers load without human intervention. Reverses automatically when mains returns.

MANUAL CHANGEOVER: Cost-effective solution for applications where brief manual intervention is acceptable. Safe, properly interlocked to prevent back-feeding.

Features & Capabilities

10 engineered capabilities — each opens the matching technical content on this page.

🧮 Calculator
1Voltage and frequency monitoring
Calculator →
2Adjustable time delays
Diagnostic Q&A →
3Under/over voltage protection
Calculator →
4Generator start signal interface
Diagnostic Q&A →
5Manual override capability
Calculator →
6LED status indicators
Diagnostic Q&A →
7Test mode for maintenance
Calculator →
8Mechanical interlocking
Diagnostic Q&A →
9Fire-resistant enclosures
Calculator →
10Optional remote monitoring
Diagnostic Q&A →

Who This Service Is For

10 industries we serve across Kenya — tap a card to message us about that specific use-case.

🔌

Hospitals and clinics

Typical project: New generator installations

💬 WhatsApp us →
🔌

Data centers

Typical project: Upgrading manual to automatic

💬 WhatsApp us →
🔌

Banks and financial institutions

Typical project: Adding generator backup to buildings

💬 WhatsApp us →
🔌

Manufacturing plants

Typical project: Solar-grid-generator hybrid systems

💬 WhatsApp us →
🔌

Hotels and restaurants

Typical project: Critical facility backup systems

💬 WhatsApp us →
🔌

Office buildings

Typical project: Temporary power setups

💬 WhatsApp us →
🔌

Residential homes

Typical project: New generator installations

💬 WhatsApp us →
🔌

Shopping centers

Typical project: Upgrading manual to automatic

💬 WhatsApp us →
🔌

Schools and universities

Typical project: Adding generator backup to buildings

💬 WhatsApp us →
🔌

Telecommunications

Typical project: Solar-grid-generator hybrid systems

💬 WhatsApp us →
📞 Call +254 768 860 665💬 WhatsApp
Live Engineering Tools

ATS & Changeovers — Interactive Engineering Panel

Tap, drag and explore. Every value is sourced from authoritative standards (NEMA Kenya, IEC, KEBS, NASA POWER, OEM data sheets) — citations appear at the foot of each widget.

🎛️ Changeover Time📋 Sense Windows & Timers (Deepsea DSE335 / ASCO 4000-series)🗺️ Open-Transition ATS Single-Line📊 Open vs Closed-Transition Comparison

Changeover Time

Standard genset ATS
6,000ms
10 ms30000 ms

IT loads need <10 ms break (use UPS). Hospital theatre lighting tolerates 0.5 s per ITIC curve. Standard ATS 6–15 s.

10–99 msStatic UPS class (no-break)
100–1500 msFast ATS with motor-driven CB
1501–10000 msStandard genset ATS
10001–30000 msManual or slow — unsuitable for IT

Source: IEC 60947-6-1 (Multifunction equipment — Transfer Switching Equipment); ITIC Curve 2000.

Sense Windows & Timers (Deepsea DSE335 / ASCO 4000-series)

Mains under-voltage trip< 0.85 pu (e.g. 204 V)IEC 60038 nominal 240 V.
Mains over-voltage trip> 1.10 pu (264 V)
Frequency window47.5 – 51.5 HzPer Energy Regulatory Commission Kenya Grid Code.
Mains-fail confirm delay0.5 – 5 s adjustable
Genset start signalAfter confirm delay
Genset warm-up before transfer5 – 10 s
Mains-return stable delay60 – 600 sAvoid hunting on flapping mains.
Cool-down before stop180 – 300 s

Source: Deepsea DSE335 operator manual; ASCO 4000-series technical document.

Open-Transition ATS Single-Line

KPLC MainsStandby GensetCB-N (mains)CB-G (gen)Mech. InterlockLoad
1Mains source

KPLC supply. ATS controller monitors V & f within window.

2Genset source

Auto-start on mains fail. Voltage builds in 5–10 s.

3Source breakers

Motor-operated MCCBs or contactors, electrically + mechanically interlocked.

4Mechanical interlock

Prevents both sources energising load simultaneously — critical safety device.

5Distribution to load

Downstream busbars feed essential circuits.

Source: IEC 60947-6-1; Schneider Electric Cahier Technique CT-209.

Open vs Closed-Transition Comparison

Open transition (break)50 ms break

50 ms minimum break — most common, lowest cost.

Delayed transition5000 ms break

Centre-off 1–10 s — used for inductive loads to avoid out-of-phase.

Closed transition (make-before-break)0 ms break

Sync check, parallels sources <100 ms — needs utility approval (KPLC).

Soft-load (peak-shave)0 ms break

Closed transition with active load ramp.

Source: IEEE 446 Recommended Practice for Emergency & Standby Power; KPLC Distribution Code.

Auto Transfer SwitchManual ChangeoverSynchronizationLoad-Shedding

🧮Generator Sizing Calculator

Generator kVA = (Load × Safety Factor) / Power Factor
Loading calculator…

Diagnostic Q&A

Live Telemetry

080
45 PSI
Oil Pressure
0120
85 °C
Coolant Temp
02000
1500 RPM
RPM

Need Expert Help?

Experienced technicians available 24/7 for ats & changeovers.

💬 WhatsApp📞 Call +254768860665

Jump to a Section on This Page

Everything for ats & changeovers lives on this page — no extra clicks, no other pages.

🎛️
Open Live Engineering Tools

Interactive knobs, charts, diagrams with sourced data

🧮
Open Sizing Calculator

Pick the right kVA on this page

📖
Read Technical Bible

Engineering brief, brands, schematics — all on this page

🏷️
Top 10 Brands Compared

Cummins, Perkins, CAT, FG Wilson, SDMO…

📐
Schematics & Diagrams

Single-line, fuel system, cooling loop

🛠️
Repair Manual

Step-by-step procedures

⚠️
Error Codes

Decode controller faults

🧰
Parts Manual

OEM part numbers & service intervals

💰
ROI & Cost Tables

Capex, opex, payback

Related Services

⚡

Cummins Generators

Cummins generator supply, installation and maintenance in Kenya. 10kVA to 2000kVA diesel generators, backed by a 2-year warranty and 1 year of free servicing on new sets.

🔧

Generator Repairs

Professional generator repair and maintenance services in Kenya. 24/7 emergency response, scheduled maintenance contracts, and annual servicing packages for all generator brands.

⚡

Distribution Boards

Design, fabrication, and installation of electrical distribution boards in Kenya. Main distribution boards, sub-boards, motor control centers, and custom panels.

🔋

UPS Systems

UPS systems sales, installation, and maintenance in Kenya. Line-interactive, online, and modular UPS. Battery replacement. All capacities from 600VA to 500kVA.

Technical Reference

The Diesel Genset Bible

ISO 8528 duty classes, sizing against real load, the alternator, control and cooling subsystems, and what commissioning has to prove.

Read the full reference →

Ready to Get Started with ATS & Changeovers?

Contact us today for a free consultation and quote. 24/7 Emergency Service Available

📞
Call Now
+254 768 860 665
💬
WhatsApp
Quick Quote

Embakasi, off Airport North Road, Nairobi 00521, Kenya

Engineering reference

Generator Control & Automation: AMF, Transfer, Synchronisation

A generator is only as good as the controller that decides when it runs, how it takes the load and when it hands back. Get the automation right and an outage is a flicker; get it wrong and the set either never starts or fights the grid. This is the logic inside modern generator control.

1. Auto Mains Failure (AMF): the start sequence

The core job of a standby controller is Auto Mains Failure (AMF): detect that the grid has failed, start the generator, prove it is healthy, transfer the load, and then reverse all of that cleanly when the grid returns. The sequence is deliberately timed — a short start delay ignores momentary dips so the set does not crank for a one-second flicker; a warm-up lets oil pressure and frequency stabilise before the load is applied; and on return, a return delay confirms the grid is genuinely back before transferring, followed by a cool-down run so the engine sheds heat before stopping.

Each of those timers exists for a reason, and badly set ones cause real problems: too short a start delay wears the starter on every flicker; no cool-down cooks the turbocharger. We commission these settings to the engine and the site, not to factory defaults, because the controller's timing is the difference between a set that lasts and one that is quietly abused on every outage.

Typical AMF timing (set to engine/site, not defaults)
TimerPurposeTypical range
Start delayIgnore momentary mains dips1–5 s
Warm-upStabilise before loading5–30 s
Transfer (break)Open-transition changeover gap0.5–2 s
Return delayConfirm mains is stable10–60 s
Cool-downShed engine heat before stop60–300 s

2. The transfer switch: open vs closed transition

The automatic transfer switch (ATS) physically moves the load between the grid and the generator, and it must be break-before-make on a standby system — never connecting the two sources together unless the controller is deliberately synchronising. A standard open-transition transfer accepts a brief dead gap (covered by a UPS on critical loads). A closed-transition transfer momentarily parallels a synchronised generator with the grid for a bumpless changeover — useful for sensitive process loads, but it requires the utility's agreement and proper protection because it ties into the grid.

A subtle but critical point: a redundant UPS behind a single, unproven transfer switch is not redundant — the ATS becomes the single point of failure. We design the transfer scheme, its interlocks and its maintenance bypass as part of the whole power system, so the changeover is something you can rely on and service safely while live.

3. Synchronisation and load sharing

When one generator is not enough — or when you want N+1 redundancy in the generation itself — multiple sets run in parallel, and that demands synchronisation: matching voltage, frequency and phase angle before the breaker closes. Close out of sync and the resulting current surge can damage alternators and trip breakers; modern controllers do this automatically in a fraction of a second. Once paralleled, the controllers share the work, balancing real power (kW) by trimming each engine's fuelling and reactive power (kVAr) by trimming each alternator's excitation.

Paralleling also enables smart operation: bringing sets on and off line as the load rises and falls so each running set stays in its efficient, wet-stacking-safe band rather than idling. For growing sites this is how capacity scales without throwing away the original investment — add a set and parallel it, rather than replacing the lot.

The synchronising conditions (all must match before closing)

V_gen ≈ V_bus f_gen ≈ f_bus phase angle ≈ 0° same phase rotation

V
= voltage magnitude
f
= frequency
phase angle
= difference between the two waveforms
Worked example — Closing a breaker with even a small phase mismatch produces a violent current transient — which is why synchronising is automated and protected, never done by eye.

4. The controllers: DSE, ComAp, PowerWizard

The brains come from a few well-proven families. DeepSea Electronics (DSE) modules are the workhorse across much of Kenya for AMF and paralleling; ComAp controllers are common on larger and more complex multi-set installations; Woodward/PowerWizard ships on many engine-OEM sets. They all do the same fundamental jobs — engine control, protection, metering, AMF and (on the right models) synchronising — but their configuration, fault codes and communication differ, which is why controller-specific expertise matters when a set will not start or a transfer misbehaves.

Beyond running the engine, these controllers are also the protection layer: over/under-voltage and frequency, over-current, oil-pressure and temperature shutdowns, over-speed, and battery monitoring. A correctly configured controller protects the asset and tells you exactly why it tripped — an incorrectly configured one either nuisance-trips or, worse, fails to protect.

5. Remote monitoring and predictive maintenance

Modern controllers expose their data — engine hours, fuel level, battery health, fault history, load — over cellular or network links, so a fleet of sets across many sites can be watched from one screen. That turns maintenance from reactive to predictive: a falling battery voltage, a creeping coolant temperature or a fuel level dropping faster than expected raises a flag before it becomes a failed start on the day of an outage.

For multi-site organisations this is transformative — instead of discovering a flat starting battery during a blackout, the system flags it days earlier on a routine alert. We integrate remote monitoring into the SLA so the generator that matters most is the one we already know is healthy, not the one we hope is.

Get your automation commissioned properly

Whether it is an AMF panel that will not transfer cleanly, a controller that needs configuring (DSE, ComAp, PowerWizard), paralleling multiple sets, or adding remote monitoring to a fleet, we design, programme and commission the control. Call +254 768 860 665 or +254 782 914 717.

References & standards

  • DeepSea Electronics (DSE), ComAp and Woodward/PowerWizard controller application notes.
  • ISO 8528-1 — generating-set control and parallel operation.
  • IEC 60947-6-1 — automatic transfer switching equipment (ATSE).
  • IEEE 1547 / utility interconnection practice for paralleling and anti-islanding.
  • Manufacturer synchronising and load-sharing (kW/kVAr) control practice.

Free diagnostic guides

Diagnosing it yourself first? Start here.

Automatic transfer switch and changeover panel faults — why a switch refuses to transfer, how to separate a control decision from a mechanical failure, and the interlock rules that exist to stop utility and generator being connected together.

  • ATS Not Changing Over — Automatic Transfer Switch Diagnosis

    8 diagnostic steps · advanced · qualified electrician

  • Generator Will Not Transfer Back to Mains

    7 diagnostic steps · intermediate · qualified electrician

  • ATS Contactor, Motor Operator and Interlock Faults — When the Switch Itself Fails

    8 diagnostic steps · advanced · qualified electrician

  • ATS Position Indication and Auxiliary Contacts — When the Panel Lies About Itself

    8 diagnostic steps · intermediate · qualified electrician

All ats & changeover panel diagnosis guidesRepair Centre

Get a quote for ats & changeovers

Tell us the site and what it has to run. We come back with a written scope and price — not a brochure range. If a smaller or simpler solution does the job, we will say so.

  • ✓Engineers on site across all 47 counties
  • ✓Genuine spare parts held in stock
  • ✓Independent — we fit the solution to your load, not to a quota

Prefer to talk? +254 768 860 665 · WhatsApp

Request a ats & changeovers quote

Four questions. We reply the same working day.