Skip to main contentSkip to navigationSkip to contactAccessibility (Alt+A)
EmersonEIMS — Reliable Power. Without Limits.
INDUSTRIES
CONTACT
Get Quote

B2BEmersonEIMS serves commercial, industrial, healthcare, telecom, hospitality, government & contractor clients.• Engineering-led • SLA-backed • Documented commissioning

Talk to an engineerWhatsApp+254 768 860 665

Services Directory

View all services →

Power & Generators

  • Cummins Generators (2-yr warranty)
  • Generator Repairs & Maintenance
  • ATS / Changeovers
  • Generator Sales
  • Generator Rental
  • Generator Installation
  • Generator Spare Parts
  • Workshop Repairs & Fabrication
  • Power Interruption Solutions

Renewable & UPS

  • Solar Energy Solutions
  • Commercial / Industrial Solar
  • Solar System Sizing
  • Solar Genius Pro™
  • UPS Systems
  • UPS Lab
  • Solar / UPS Hub
  • Borehole Pumps

Electrical & HVAC

  • Distribution Boards & Panels
  • Motor Rewinding
  • Motors & Drives
  • High-Voltage Systems
  • Diesel Automation
  • Industrial Controls
  • Steel Fabrication
  • AC / HVAC Installation

Specialised & AI Suites

  • Hospital Incinerators
  • Incinerator Construction Guide
  • Building Engineering Suite
  • EIMS PRO Workspace
  • AquaScan Pro™
  • Generator Oracle™
  • Plant & Equipment Oracle
  • Diagnostics Hub
  • Troubleshooting Wizard

Maintenance Hubs

  • Generator Maintenance
  • Solar Maintenance
  • HVAC Maintenance
  • Borehole Maintenance
  • Electrical Maintenance
  • Motors Maintenance
  • Incinerator Maintenance
  • Fabrication & Welding

Resources & Tools

  • Repair Centre — 60 free guides
  • Spare Parts Marketplace
  • Sectors We Serve
  • Brands We Service
  • All Engineering Tools
  • Resources & Learning Hub
  • Knowledge Base
  • Technical Bible
  • Power Calculators
  • Fault Code Database
  • Blog & Articles
  • FAQ
  • Emergency Response Guide

Service Areas

  • All Kenya — 47 Counties
  • Nairobi
  • Mombasa
  • Kisumu
  • Nakuru
  • Kiambu
  • All Service Locations
  • East Africa
  • Kampala, Uganda
  • Dar es Salaam, Tanzania
  • Kigali, Rwanda
  • Juba, South Sudan
  • Site Directory — every page
EMERSONEiMS

Engineering-grade reliability for East Africa's critical infrastructure. Power systems built to perform.

  • X↗
  • Facebook↗

Company

  • About Us
  • All Services
  • Prices & Costs
  • Book a Service
  • Project Gallery
  • Case Studies
  • Industries Served
  • Careers
  • Contact Us

Quick Links

  • Generator Sales
  • Solar Energy
  • Diagnostic Suite
  • Solar / UPS Hub
  • Generator Oracle
  • Knowledge Base
  • FAQ

Contact

  • Nairobi HQEmbakasi, off Airport North Road, Nairobi
    (Near KEMSA Head Office)
  • Department Emails
    • General Inquiriesinfo@emersoneims.com
    • Service Coordinationemersoneimservices@emersoneims.com
    • Generator Deskgenerators@emersoneims.com
    • Solar & UPS Desksolar@emersoneims.com
    • Sally — Direct Accountsally@emersoneims.com
  • Phone
    +254782914717
    +254768860665

© 2026 Emerson EiMS. All rights reserved.

PROTECTED BY GENERATOR ORACLE / EMERSONEIMS
Privacy PolicyTerms of Service
ENGINEERED IN NAIROBI, KENYA

Keyboard Shortcuts

  • Alt + A: Open accessibility settings
  • Tab: Navigate to next element
  • Shift + Tab: Navigate to previous element
  • Enter or Space: Activate buttons and links
  • Escape: Close dialogs and menus
  • Arrow keys: Navigate within menus and sliders
  • Home: Go to beginning of list
  • End: Go to end of list
Fault codes / Kohler

Kohler generator fault codes

Every Kohler engine fault code in our verified reference — 24 codes, 18 of them with a documented remedy. Find your code in the table, read the likely causes, then work the remedy. If it is beyond a field fix, our workshop in Embakasi repairs Kohler controllers and engines at board level.

Covers: 14RES/RESL and 20RES/RESL · C13/C15/C18

Kohler generator engine fault codes with causes and remedies
CodeFaultLikely causeRemedy
91-2Accelerator Pedal Position 1: ErraticIntermittent; indicating a failure or overload.—
91-3Accelerator Pedal Position 1: Voltage Above Normaltriggering a shutdown.Check for shorts to power. Inspect sensor. Replace if necessary.
91-4Accelerator Pedal Position 1: Voltage Below NormalLocate and release the emergency stop button on the APM303 panel by twisting or pulling as per design. Check for safety conditions that triggered the activation. Inspect the button’s wiring for faults. Reset the fault on the control panel and attempt to restart. If the fault persists; consult the SDMO APM303 or a technician.Check for open circuits. Inspect sensor. Replace if necessary.
91-8Accelerator Pedal Position 1: Abnormal FrequencyPulse Width; shorts; opens). Replace the sensor if faulty. Prime the fuel system if needed. Reset the fault and restart. to the APM303 or a technician if unresolved.Check the fuel level in the daily tank; refill with clean diesel fuel. Inspect for fuel leaks in the tank or lines. Test the fuel level sensor and wiring for faults (e.g.
97-3Water In Fuel Indicator: Voltage Above Normalworn pump). Reset the fault and restart. Consult the APM303 or a technician if unresolved.Check wiring for shorts to power. Inspect switch. Replace if necessary.; Check the engine oil level; top up with the recommended oil if low. Inspect for oil leaks. Test the oil pressure sensor and wiring for faults; replace if defective. Perform an oil pressure test to check for internal engine issues (e.g.
100-3Engine Oil Pressure: Voltage Above Normal—Check sensor wiring for shorts. Inspect oil pressure sensor. Replace if faulty.; Check the coolant level; top up if low. Inspect the cooling system for leaks or blockages. Ensure the radiator is clean and vents are clear. Test the coolant temperature sensor and wiring; replace if faulty. Verify thermostat operation. Reset the fault and restart. Consult the APM303 or a technician if unresolved.
100-4Engine Oil Pressure: Voltage Below Normal1500 RPM for 50 Hz). Inspect the governor or throttle for miscalibration or faults. Check the fuel system for over-fueling issues. Test the speed sensor and wiringCheck for open circuits. Inspect sensor. Replace if necessary.; Verify the engine speed is within nominal limits (e.g.; replace if faulty. Reset the fault and restart. to the APM303 or a technician if unresolved.
486-3Engine Fan Reverse Switch: Voltage Above Normalcausing a shutdown.Check wiring and connections for shorts to power. Inspect fan reverse switch. Replace if faulty.
486-4Engine Fan Reverse Switch: Voltage Below Normalpreventing optimal engine starting conditions.Check for open circuits or poor connections. Inspect fan reverse switch. Replace if faulty.
544-2Engine Cooling Fan Speed Sensor: ErraticIntermittent; preventing engine start and triggering a shutdown.—
544-8Engine Cooling Fan Speed Sensor: Abnormal FrequencyPulse Width; indicating a potential fault.—
774-2Accelerator Pedal Position 2: ErraticIntermittent; opens; or loose terminals. Test the relay for proper operationInspect the differential relay wiring and connections for shorts; replace if faulty. Verify the relay settings match the generator specifications. Reset the fault and test operation. to the SDMO or a technician if unresolved.
774-3Accelerator Pedal Position 2: Voltage Above Normalopens; or loose terminals. Test the monitor for proper operationCheck for shorts to power. Inspect sensor. Replace if necessary.; Check the insulation monitor wiring and connections for shorts; replace if faulty. Verify the monitor settings are correct. Reset the fault and test operation. Consult the SDMO or a technician if unresolved.
774-4Accelerator Pedal Position 2: Voltage Below Normalindicating a warning.Check for open circuits. Inspect sensor. Replace if necessary.
774-8Accelerator Pedal Position 2: Abnormal FrequencyPulse Width; preventing charging and triggering a shutdown.—
1076-5Engine Cooling Fan Bypass Solenoid: Current Below Normaltriggering a shutdown.Check solenoid wiring for open circuits. Test solenoid. Replace if necessary.
1076-6Engine Cooling Fan Bypass Solenoid: Current Above Normal—Check for shorts to ground. Inspect solenoid. Replace if faulty.; Inspect the generator’s electrical output cables and connections for insulation breakdown or damage. Test the insulation resistance using a megger. Check the insulation monitor wiring and settings. Reset the alarm and test operation. to the SDMO or a technician if the alarm persists.
1937-2Engine Coolant Flow Switch: ErraticIntermittent; triggering a shutdown.—
LCbLow cranking voltageCharge or replace the battery.; opens; or loose connections. Verify the module is correctly installed and powered. Reset the control panel and test communication. If unresolvedCheck the CAN bus wiring and connectors for the option 6 module for shorts; replace the module or to the SDMO or a technician.
Lead 13 and Ground (Low Oil Pressure - LOP Switch)Checks continuity of the low oil pressure switchindicating oil pressure status.; ensure it is not stuck open. Inspect contactor wiring and control signals for faults. Verify ATS configuration. Reset the alarm and test operation. Consult the SDMO or a technician if the issue persists.Check the emergency power contactor (generator side) for proper operation
LOPLow oil pressureopens; or loose connections. Verify the spare module is powered and correctly configured. Reset the control panel and test communication. If the fault persists; consult the SDMO or a technician.Check the engine oil level regularly as recommended in the O/M. Check for leaks in the lubrication system. Check the oil level and add oil if the level is low. Check low oil pressure switch connections and operation. Check the oil pump and lubrication system. O/M 5.10 Engine S/M.; Inspect the RS485 communication cables and connectors for shorts
LrLocked rotor5.4.; Power cycle the generator by disconnecting the battery for 30 seconds and reconnecting. Check for software updates for the control panel. Inspect control panel wiring for faults. If the fault persists; the control module may need replacement. Consult the SDMO or a technician.Check mag pickup connections and operation. Check for a locked rotor. 5.9.4
P1-9 and P1-10 (Temperature Sensor - CTS)Checks the resistance of the coolant temperature sensorindicating engine temperature.Verify the normal power contactor (system side) is functioning and not stuck open. Inspect contactor wiring and control signals for faults. Check the automatic transfer switch (ATS) settings. Reset the alarm and test operation. to the SDMO or contact a technician if unresolved.
QCON1 and QCON2 (Magnetic Pickup)Checks resistance of the magnetic pickupused for engine speed sensing.; triggering a shutdown.—

Codes and descriptions are industry-standard identifiers reproduced for identification only. This reference is not affiliated with or endorsed by Kohler; for official procedures always refer to the manufacturer’s service manual for your specific engine. A dash means our registry holds no verified entry for that column — we publish the gap rather than fill it in.

Cannot clear the fault?

Send us the code and the engine serial. We diagnose Kohler sets on site across all 47 counties, and repair controllers at board level on the bench in Embakasi.

Fault codes for other engines

  • Caterpillar547
  • Perkins520
  • Cummins500
  • Deutz252
  • SDMO118
  • Atlas Copco75
  • Weichai45
  • Generac30
  • Cummins Onan26