47-Point Generator Maintenance Checklist

The ultimate maintenance guide to extend your generator lifespan. Daily, weekly, monthly, and annual maintenance tasks explained by our expert technicians.

By Emerson Service Team10 January 202512 min read

Why Maintenance Matters

A well-maintained generator can last 20,000+ hours. Neglected ones fail at 5,000 hours. That's the difference between 20 years and 5 years of service.

Our 47-point checklist covers everything you need to keep your generator running perfectly.

DAILY CHECKS (5 minutes)

Do these every day your generator runs:

#

Visual Inspection 1. ✅ Check for oil leaks under and around the generator 2. ✅ Look for fuel leaks around connections and filters 3. ✅ Check coolant level in reservoir (don't open hot radiator!) 4. ✅ Inspect battery terminals for corrosion 5. ✅ Verify all guards and covers are in place

#

Operational Checks 6. ✅ Check oil level with dipstick (should be between marks) 7. ✅ Verify fuel level is adequate 8. ✅ Listen for unusual sounds during operation 9. ✅ Check exhaust color (should be clear or light gray) 10. ✅ Monitor control panel for warning lights

WEEKLY CHECKS (15 minutes)

#

Engine System 11. ✅ Check air filter condition (hold up to light - should see through) 12. ✅ Inspect drive belts for cracks, fraying, proper tension 13. ✅ Check radiator fins for debris/damage 14. ✅ Verify coolant hoses are tight and not cracked 15. ✅ Test battery voltage (should be 12.5V+ when off, 14V+ charging)

#

Fuel System 16. ✅ Drain water separator/fuel filter 17. ✅ Check fuel lines for cracks or leaks 18. ✅ Verify fuel tank vent is clear 19. ✅ Inspect fuel cap seal

#

Electrical 20. ✅ Check all cable connections are tight 21. ✅ Verify ground connection is secure 22. ✅ Inspect control panel for any loose wiring 23. ✅ Test emergency stop button functions

MONTHLY CHECKS (30 minutes)

#

Deep Inspection 24. ✅ Clean air filter or replace if damaged 25. ✅ Check alternator belt tension and condition 26. ✅ Inspect exhaust system for leaks 27. ✅ Clean battery terminals and apply protector 28. ✅ Check ATS (Automatic Transfer Switch) operation

#

Testing 29. ✅ Run generator under load for 30 minutes minimum 30. ✅ Check all gauges: oil pressure, water temp, voltage, frequency 31. ✅ Test automatic start function (if equipped) 32. ✅ Verify output voltage under load (should be 240V ±5%) 33. ✅ Check frequency stability (should be 50Hz ±1Hz)

#

Documentation 34. ✅ Record running hours 35. ✅ Log fuel consumption 36. ✅ Note any observations or concerns 37. ✅ Update maintenance log

QUARTERLY CHECKS (1-2 hours)

#

Oil & Filters 38. ✅ Change engine oil (or at manufacturer intervals) 39. ✅ Replace oil filter 40. ✅ Replace fuel filter(s) 41. ✅ Replace air filter element

#

Cooling System 42. ✅ Test coolant concentration with refractometer 43. ✅ Check thermostat operation 44. ✅ Clean radiator externally 45. ✅ Inspect water pump for leaks

#

Electrical System 46. ✅ Test battery load capacity 47. ✅ Check starter motor engagement

SERVICE INTERVALS TABLE

Component Interval Notes | |




--|


-|

-| Engine oil 250 hours or 6 months Use manufacturer grade | Oil filter Every oil change Quality filters only | Fuel filter 500 hours or annually Check monthly | Air filter 500 hours or as needed Clean weekly | Coolant 2,000 hours or 2 years Use proper mix | Spark plugs (petrol) 500 hours Gap to spec | Injectors (diesel) 2,000 hours Professional service | Valve adjustment 2,000 hours Professional service | Full overhaul 10,000-15,000 hours Major service |

WARNING SIGNS - CALL US IMMEDIATELY

🚨 Engine:

  • Blue or black exhaust smoke
  • Knocking or unusual sounds
  • Oil pressure drops below normal
  • Excessive vibration

    🚨 Electrical:

  • Output voltage fluctuations >10%
  • Frequency instability
  • Warning lights staying on
  • Burning smell from control panel

    🚨 Cooling:

  • Coolant leaking
  • Temperature above normal
  • Coolant discolored or oily
  • Radiator damage

    🚨 Fuel:

  • Diesel in oil (dipstick smells like fuel)
  • Black smoke
  • Hard starting
  • Fuel consumption increased

    COMMON MAINTENANCE MISTAKES

    1. Ignoring the air filter - Dirty filter kills engines faster than anything 2. Wrong oil type - Always use manufacturer-specified grade 3. Skipping load tests - Generators need regular exercise 4. Letting fuel sit - Diesel degrades, use stabilizer for storage 5. Ignoring small leaks - Today's drip is tomorrow's failure 6. DIY injector work - Always use professionals for fuel injection 7. Cheap filters - Genuine/quality filters protect your investment

    STORAGE PROCEDURES

    If not using for extended periods:

    1. Run generator for 30 minutes at load to warm thoroughly 2. Drain fuel or add stabilizer (follow directions) 3. Change oil while engine is warm 4. Fog engine if storing 3+ months 5. Disconnect battery and store separately 6. Cover generator but allow ventilation 7. Run monthly for 30 minutes under load

    FREE MAINTENANCE SERVICE

    Emerson Energy offers comprehensive maintenance packages:

    Package Coverage Price | |




    |


    -|

    -| Basic Quarterly service, parts extra KES 8,000/year | Standard Quarterly + emergency calls KES 15,000/year | Premium Monthly visits + all parts KES 35,000/year | Enterprise 24/7 coverage + priority Custom quote |

    All packages include:

  • Certified technicians
  • Genuine/OEM parts
  • Detailed service reports
  • WhatsApp support

    Schedule Your Service

    📞 Call: +254 768 860 665 or +254 782 914 717 📍 WhatsApp: Send your generator model for instant quote 🏠 Coverage: All 47 counties in Kenya


    *Keep this checklist handy! Print it and post near your generator.*